Home>News Center>News Center>The new residential building in the town is required to be adjusted to four floors.

The new residential building in the town is required to be adjusted to four floors.

发布日期:2019-02-25  来源:Beijing Daily  

Core Tip: The Ministry of Housing and Urban-Rural Development recently sought advice on 38 residential and urban-rural construction projects in the “Standards for Residential Projects”. According to the new regulations, new residential buildings in urban areas should be fully renovated and delivered. new

The Ministry of Housing and Urban-Rural Development recently stated the "Standards for Residential Projects"38Consultation on engineering specifications in the field of housing and urban and rural construction. According to the new regulations, new residential buildings in urban areas should be fully renovated and delivered. New regulations also improve residential settingselevatorRequirements from the original seven floors and above or beyond16Set up the elevator, adjusted to four or more floors or more9The meter should be equipped with an elevator.

It is proposed in this Code that new urban residential buildings should be fully renovated and delivered, and should meet the following requirements: the fixed surface and pipelines of all functional spaces in indoors and public parts should be fully paved or painted; water supply and drainage, gas, Lighting, power supply and other systems and kitchen and toilet facilities should be installed in place; water supply, power supply, gas, roads, green spaces, parking spaces, garbage and sewage treatment and other planning facilities should have conditions of use; fire facilities should be intact, fire exits should be smooth.

In terms of housing layout, the size of the casing consisting of bedroom, living room, kitchen and bathroom should not be less than30Square meter; a set (opening) consisting of a bedroom, kitchen and bathroom, which is also a living room, and its use area should not be less than22Square meters.

The use area of the double bedroom should not be less than the use area of the bedroom.9Square meter; single bedroom use area should not be less than5Square meter; the living area of the bedroom should not be less than12Square meters. The living room area should not be less than10Square meters. The use area of the kitchen should not be less than3.5Square meters. Each house should be equipped with at least three sanitary devices: toilet, bath and face washer. When three sanitary appliances are centrally placed in the same bathroom, the area of use should not be less than2.2Square meters.

The "Residential Project Code" also requires elevators, and the height of the four-storey and four-storey residential buildings, or the entrance floor of the residents, is higher than the outdoor design floor.9New residential buildings in M. should be equipped with elevators, and stations should be set up on each floor with household doors and public corridors.

Each living unit in which the elevator is installed shall have at least one elevator that can accommodate the stretcher, and the size of the elevator car should not be less than1.5Meter×1.6Meter, the net width of the car door should not be less than0.9Meters; for residential buildings of 12 and 12 floors, there should be no less than two elevators per living unit, and no less than one elevator can be installed to accommodate the stretcher.

Interpretation

Housing should consider the convenience of the elderly

Compared with the original regulations, the new regulations have improved the requirements for residential elevators, from the original seven floors and above or beyond16Set up the elevator, adjusted to four or more floors or more9Meters should be provided with elevators; one unit for each of the twelve floors and above can be used to accommodate the stretcher, and one for each unit of four or more floors is provided with a barrier-free elevator that can accommodate the stretcher. The elevator is an important vertical transportation for the house. In China, it is stipulated that elevators should be installed on the seventh floor and above.

The Ministry of Housing and Urban-Rural Development said that China has entered an aging society. With the development of society and the improvement of living standards, housing should pay more attention to the convenience of the elderly and the convenience of ordinary residents.